Battery Backup

 
SHOPPING CART

You have no items in your shopping cart.

Free shipping
On all Orders Over $750.00

You're currently on:

Pump Sentry 812

Pump Sentry 812

More Views

Untitled document

Battery Back Up Power
For Sump and Immersible Pumps

Part Number: 812 PS
  • Buy 2 for $518.00 each and save 8%

  • Manufacturer:
  • SEC America

  • Warranty:
  • 1 Year Warranty

  • Qty:
  • Availability: In stock

    Price: 
    $558.00
      

Options / Accessories

Options Product Name Price Qty
Battery Cables for Pump Sentry & Sure Fire Stove Sentry Battery Cables for Pump Sentry & Sure Fire Stove Sentry
Price: 
$17.00
Special Price: 
$15.00

Product Description

Untitled document

Here's How Pump Sentry Works

Battery Back Up
For Sump Pumps

1200 Watt Capacity

812PS Pump Sentry interfaces between a pump and its AC wall outlet. When AC utility power is present, the 812PS charges a battery and monitors the wall outlet to detect a power outage. At the moment utility power fails, the 812PS draws energy from a battery and converts it to enable pump operation. When utility power returns, the 812PS automatically switches the pump back to AC wall outlet power. At the same time, the 812PS resumes charging the battery to return it to full capacity in preparation for the next power failure.

Pump Sentry interfaces between a pump and the AC electrical supply.

When electricity is available, Pump Sentry charges a battery and monitors the power line to detect a power outage. At the instant that power failure occurs, Pump Sentry draws the energy stored in the battery and converts it to AC power. This AC power is automatically channeled to the pump to maintain its operation in the absence of electricity.

When AC utility power is restored, the Pump Sentry reinstates AC utility power as the prime energy source to operate the pump. Simultaneously and automatically Pump Sentry commences the recharging of the battery, to return it to full capacity in preparation for the next power failure.

Features

  • Rugged Aluminum Housing
  • Battery Cables Included
  • Compact Size
  • For Wall Mount or Surface Mount Installation
  • 2 Year Factory Warranty

Advantages

  • Operates Common AC Pumps
  • Instant Automatic Power Transfer
  • Supports Full Pump Capacity
  • Does Not Occupy Sump Pit Space
  • Can Be Easily Installed
  • Silent and Clean Operation

Pump Compatibility

    Designed to operate most 1/3 Hp. sump pumps manufactured by:

  • Hydromatic
  • Jacuzzi
  • Stevens
  • Zoeller
  • Tecumseh
  • Wayne
  • Most column pumps
How to Calculate Operating Time During Power Outage
Operating time will depend on the following:
a) The size of the battery bank i.e. its total Ampere-Hour (A-hr) capacity
Ampere-Hour capacity is calculated by adding the A-hr ratings of
all the batteries in the battery bank where the batteries are connected in parallel.
(For Parallel Connection See Fig. #1)
b) The current draw for the pump in Amps (C).
This can be read off the nameplate on the sump pump
c) The average operating duty cycle of the system
The duty cycle of a system is the ratio of its "on" time to its "on" time plus "off" time
e.g. if a pump will work for 10 seconds and is then off for two minutes (120 seconds)
its duty cycle is calculated as follows:
Duty cycle = 10/(10+120) = 0.077
Once (a) (b) and (c) are known the operating time of a pump sentry
in hours can be calculated by the formula:
T = A-hr/(C x 10 x D)
e.g. for a system with 1 battery rated 90 A-hr.
1) 1 battery rated 90 A-hr., A-hr = 1 x 90
2) A sump pump that draws 9 Amps, C=9
3) Duty cycle which operates 10 seconds "on" followed by
3 minutes (180 seconds) "off", D = 10/(10+180) = 0.053
T (Hours) = (1x 90)/(9 x 10 x 0.053) = 19
In 10 seconds the average 1/3 hp. sump pump will
evacuate approximately 10 gallons of water.

Untitled document

Pump Sentry Model 812

Electrical Specifications  Model 812 PS  
Normal Mode Operation:    
Input Voltage:  100-128 VAC 
Input/Output Current (max.)  11 A Continuous 
On Motor Start Up  15 A Peak 
Max. Battery Charging Current  12 A 
Max. Recharge Time  13 Hrs. 
(For recharging a 180 minute reserve battery that has been depleted to 10.5 Vdc)

Back Up Mode Operation:
Maximum Back Up Power  1200 Watts Cont. 
Maximum Input Current  120 A Cont. 
Size: (inches)  3H x 8W x 17L 

Model 812 PS will operate most pumps whose continuous current draw does not exceed 11 A.

Pump Sentry Selector Guide**

Manufacturer Pump Model  812 PS 

Submersible Types     
Hydromatic SD 25A
Jacuzzi 3SPP
Stevens SS45F
Zoeller M 53 
Tecumseh T157
Column Types  
Any Brand   


**Models other than those listed above may operate properly with Pump Sentry

Untitled document

Battery Back Up
For Sump Pumps

1200 Watt Capacity

812PS Pump Sentry interfaces between a pump and its AC wall outlet. When AC utility power is present, the 812PS charges a battery and monitors the wall outlet to detect a power outage. At the moment utility power fails, the 812PS draws energy from a battery and converts it to enable pump operation. When utility power returns, the 812PS automatically switches the pump back to AC wall outlet power. At the same time, the 812PS resumes charging the battery to return it to full capacity in preparation for the next power failure.

Pump Sentry interfaces between a pump and the AC electrical supply.

When electricity is available, Pump Sentry charges a battery and monitors the power line to detect a power outage. At the instant that power failure occurs, Pump Sentry draws the energy stored in the battery and converts it to AC power. This AC power is automatically channeled to the pump to maintain its operation in the absence of electricity.

When AC utility power is restored, the Pump Sentry reinstates AC utility power as the prime energy source to operate the pump. Simultaneously and automatically Pump Sentry commences the recharging of the battery, to return it to full capacity in preparation for the next power failure.

Features

  • Rugged Aluminum Housing
  • Battery Cables Included
  • Compact Size
  • For Wall Mount or Surface Mount Installation
  • 2 Year Factory Warranty

Advantages

  • Operates Common AC Pumps
  • Instant Automatic Power Transfer
  • Supports Full Pump Capacity
  • Does Not Occupy Sump Pit Space
  • Can Be Easily Installed
  • Silent and Clean Operation

Pump Compatibility

    Designed to operate most 1/3 Hp. sump pumps manufactured by:

  • Hydromatic
  • Jacuzzi
  • Stevens
  • Zoeller
  • Tecumseh
  • Wayne
  • Most column pumps

 
In the absence of electricity, Pump Sentry will convert power from a deep cycle marine battery of 180 minutes reserve capacity, to operate a 1/3 horsepower sump pump. Under typical duty cycle conditions such operation can be maintained for approximately two days. If more time is desired, a larger battery or multiple batteries can be used (see Figure 2). The operating time is directly proportional to the battery capacity.


Shipping Maps


Write Your Own Review

You're reviewing: Pump Sentry 812

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Value
Quality
Price


© 2010 Alternative Heating and Supply.