You have no items in your shopping cart.
You have no items in your shopping cart.
The Surefire Stove Sentry interfaces between a pellet stove or kerosene heater and the AC electrical supply.
SF 503A interfaces between a heating appliance (wood pellet or alternative fuel stove) and its AC wall outlet. When AC utility power is present, the SF 503A charges a battery and monitors the wall outlet to detect a power outage. At the moment utility power fails, the SF 503A draws energy from a battery and converts it to enable appliance operation. When utility power returns, the SF 503A automatically switches the appliance back to AC wall outlet power. At the same time, the SF 503A resumes charging the battery to return it to full capacity in preparation for the next power failure.
This is same product as the stove companies are selling at a LOWER Cost!
503A is used on:
Lennox / Whitfield Profile 20 & 30, the Advantage II T, Advantage Optima 2 & 3.
Traditions T3000P-2
Jamestown J1000B Baby Bear & Babe Bear Ins.
Thelin Little Gnome & Parlour
Hearth & Home Quadrafire Castile, Santa Fe, Classic Bay 1200 & Mt Vernon
Dansons All Dansons Models
Bixby Energy Systems The Bixby stove model 110
When electricity is present the Surefire Stove Sentry charges a battery and surveys the power line. At the instant that a power failure occurs, the Surefire Stove Sentry converts the energy stored in the battery to AC power. This assures operation of the pellet stove or kerosene heater without interruption during the absence of electricity.
When AC utility power is restored, the Surefire Stove Sentry reinstates AC utility power as the prime energy source to operate the pellet stove or kerosene heater. Simultaneously and automatically the Surefire Stove Sentry commences the recharging of the battery, to return it to full capacity in preparation for the next power failure.
At sites where utility power is not present, the user should determine if there is a sufficient reserve of battery capacity to enable the pellet stove or kerosene heater to operate for the desired time period. Consult the Surefire Stove Sentry operating manual for data relating the size and number of batteries needed.
Figure 1 illustrates the interconnections between the pellet stove or kerosene heater, Surefire Stove Sentry and battery.
Model SF 503A
Normal model Operation
(Supplying Line Power)
Input Voltage Range 100-128 VAC
Input Current 7.0 A
Charging Current (max.) 12A
Recharge Time (max.) 13 Hours
(FOR 90 A-HR. BATTERY Fully Discharged)
Back Up Mode Operation
(Supplying Battery Power)
Maximum Back Up Power 750 Watts
Maximum Input Current 70 A
Factory Warranty 1 year
Dimensions (L x W x H) in. 17 x 7 x 3
Weight (lbs.) 16
Models SF 707 and SF 709 will operate most pellet stoves. The user should ensure that his stove's power consumption is less than the maximum back up power specifications of the stove/heater sentry.
How to Calculate Backup Operating Time |
Determining operating time requires the following inputs: |
a) The size of the battery bank |
i.e. its total Ampere-Hour (A-hr) capacity |
Ampere-Hour capacity is calculated by adding the A-hr ratings |
of all of the batteries in the battery bank where the batteries are |
connected in parallel. |
(For Parallel Connection See Fig. #1) |
b) The current draw for the sentry in Amps (C). |
This can be computed by summing all of the electrical loads |
which the sentry is expected to operate |
c) The average operating duty cycle of the system |
The duty cycle of a system is the ratio of its "on" time |
e.g. if a water circulation pump will work for one minute and is |
then off for two minutes, its duty cycle is calculated as follows: |
e.g. in the case of a pellet stove which has no off time |
d) Once (a) (b) and (c) are known the operating time of |
the sentry (in hours) can be calculated by the formula: |
e.g. for a system with 3 batteries each rated 90 A-hr. |
1) 3 batteries each rated 90 A-hr., A-hr = 3 x 90 |
2) A load that draws 4 Amps, C=4 |
3) Duty cycle which operates 1 minute "on" followed |
by 3 minutes "off", D = 1/(1+3) = 0.25 |
T (Hours)= (3 x 90)/(4 x 10 x 0.25) = 27 |
503A is used on:
Lennox / Whitfield Profile 20 & 30, the Advantage II T, Advantage Optima 2 & 3.
Traditions T3000P-2
Jamestown J1000B Baby Bear & Babe Bear Ins.
Thelin Little Gnome & Parlour
Hearth & Home Quadrafire Castile, Santa Fe, Classic Bay 1200 & Mt Vernon
Dansons All Dansons Models
Bixby Energy Systems The Bixby stove model 110
Shipping Maps
| Price |
|
| Value |
|
| Quality |
|
Bought this Item and wasn't sure if it would do the job. It works great and worked easily and was so easy to install. Would recommend to any person looking into these. (Posted on 11/4/11)
Order before 3pm for same day shipping! We Ship UPS. Map below show estimated shipping time for ground. At checkout you can choose other shipping options. Thanks for shopping with us!


loading...